QuickPrep

QuickPrep is a suite of features for exploring protein-ligand interactions. An automated procedure to prepare a protein-ligand structure is included, which adds hydrogens and sets protonation states, fixes receptor atoms far from the ligand (so they are constrained not to move), and leaves receptor atoms near the ligand (in the active site) free to move, though subject to tether restraints that discourage gross movement. The ligand and solvent atoms can be either free to move or also subject to tethers. Please note that the tethers and fixed atom flags are lost on export.

Options

Molecule Field
Field containing the raw complexes
Overwrite Molecule
If on input field will be overwritten.
Field Suffix
Name suffix for cleaned complexes
Use Structure Preparation
If on, Structure Preparation will be used to correct issues diagnosed in the protein using default fixes. Otherwise, the structure will be used as is.
Use Protonate3D for Protonation
If on, Protonate3D will be used to add hydrogens and assign ionization states. Otherwise, hydrogens will be added in default extended conformations.
Allow ASN/GLN/HIS flips in Protonate3D
If on, side chain flips will be permitted for terminal amide, sulfonamide and imidazole groups in the Protonate3D calculation (which must be enabled).
Water Molecules Farther than 4.5 A from Ligand or Receptor
If on, waters farther than 4.5 angstroms from either the ligand or the receptor will be deleted.
Cap Breaks and Delete Sequence
If on, chain breaks will be kept and empty residues deleted.
Receptor
Enable receptor tethering
Strength
The force constant used for the restraints of receptor atoms.
Buffer
The size (in angstroms) of the flat-bottom restraint given to receptor atoms. No restraint forces will be applied for distances less than the specified value.
Tether Hydrogens
If on, hydrogens will be tethered.
Ligand
Enable Ligand tethering
Strength
The force constant used for the restraints of ligand atoms.
Buffer
The size (in angstroms) of the flat-bottom restraint given to ligand atoms. No restraint forces will be applied for distances less than the specified value.
Tether Hydrogens
If on, hydrogens will be tethered.
Solvent
Enable Solvent tethering
Strength
The force constant used for the restraints of solvent atoms.
Buffer
The force constant used for the restraints of solvent heavy atoms. The size (in angstroms) of the flat-bottom restraint given to solvent atoms. No restraint forces will be applied for distances less than the specified value.
Tether Hydrogens
If on, hydrogens will be tethered.
Retain QuickPrep Minimization Restraints
If enabled, any restraints used in the minimization (i.e. Fix/Tether) will be retained when the calculation terminates
Atoms
If on, atoms farther than the specified distance from a ligand will be fixed (in addition to tethers). A value of zero will fix all non-ligand atoms.
Farther than x angstrom from ligands. x
Keep atoms more than x angstroem away from the ligands as fixed.
Hydrogens Close to Ligands will not be fixed
If on, hydrogens close to the ligand will be free; otherwise, hydrogens near the ligand will be fixed.
Refine Complex
Allow to refine the final complex
to an RMS Gradient of
Gradient in kcal/mol/A
Forcefield
Forcefield used for the geometry optimization
Solvation
Solvation model used during the forcefield calculations
Thread Count
Threadcount as used in Potential Setup
Exterior Dielectric
Exterior Dielectric Constant
Interior Dielectric
Interior Dielectric Constant

Input Ports

Icon
Raw Complexes

Output Ports

Icon
Cleaned Complexes

Popular Predecessors

  • No recommendations found

Popular Successors

  • No recommendations found

Views

QuickPrep
Summary

Workflows

Links

Developers

You want to see the source code for this node? Click the following button and we’ll use our super-powers to find it for you.